adjust_reason_t | "Adjust Reason" field of the Current Time characteristic |
ant_bpwr_common_data_t | Data structure for BPWR common data |
ant_bpwr_disp_cb_t | Bicycle Power Sensor RX control block |
ant_bpwr_disp_config_t | Bicycle Power Display configuration structure |
ant_bpwr_page16_data_t | Data structure for Bicycle Power data page 16 |
ant_bpwr_page1_data_t | Data structure for Bicycle Power data page 1 |
ant_bpwr_page_torque_data_t | Common data structure for Bicycle Power data pages 17, 18 |
ant_bpwr_profile_s | Bicycle Power profile structure |
ant_bpwr_sens_cb_t | Bicycle Power Sensor control block |
ant_bpwr_sens_config_t | Bicycle Power Sensor configuration structure |
ant_bpwr_simulator_cb_t | BPWR simulator control block structure |
ant_bpwr_simulator_cfg_t | BPWR simulator configuration structure |
ant_bpwr_simulator_t | BPWR simulator structure |
ant_bsc_combined_page0_data_t | Data structure for Bicycle Combined Speed and Cadence data page 0 |
ant_bsc_disp_cb_t | BSC Display control block |
ant_bsc_disp_config_t | BSC Display configuration structure |
ant_bsc_page0_data_t | Data structure for BSC data page 0 |
ant_bsc_page1_data_t | Data structure for BSC data page 1 |
ant_bsc_page2_data_t | Data structure for BSC data page 2 |
ant_bsc_page3_data_t | Data structure for BSC data page 3 |
ant_bsc_page4_data_t | Data structure for BSC data page 4 |
ant_bsc_page5_data_t | Data structure for BSC data page 5 |
ant_bsc_profile_s | BSC profile structure |
ant_bsc_sens_cb_t | BSC Sensor control block |
ant_bsc_sens_config_t | BSC Sensor configuration structure |
ant_bsc_simulator_cb_t | BSC simulator control block structure |
ant_bsc_simulator_cfg_t | BSC simulator configuration structure |
ant_bsc_simulator_t | BSC simulator structure |
ant_channel_config_t | ANT channel configuration structure |
ant_common_page70_data_t | Data structure for ANT+ common data page 70 |
ant_common_page80_data_t | Data structure for ANT+ common data page 80 |
ant_common_page81_data_t | Data structure for ANT+ common data page 81 |
ant_encrypt_adv_burst_settings_t | Advanced burst settings used by the encrypted channel |
ant_encrypt_channel_settings_t | ANT channel cryptographic configuration |
ant_encrypt_info_settings_t | ANT encryption information |
ant_encrypt_stack_settings_t | ANT stack cryptographic configuration |
ant_evt_t | ANT stack event |
ant_hrm_page0_data_t | Data structure for HRM data page 0 |
ant_hrm_page1_data_t | Data structure for HRM data page 1 |
ant_hrm_page2_data_t | Data structure for HRM data page 2 |
ant_hrm_page3_data_t | Data structure for HRM data page 3 |
ant_hrm_page4_data_t | Data structure for HRM data page 4 |
ant_hrm_profile_s | HRM profile structure |
ant_hrm_sens_cb_t | HRM Sensor control block |
ant_hrm_sens_config_t | HRM sensor configuration structure |
ant_hrm_simulator_cb_t | HRM simulator control block structure |
ant_hrm_simulator_cfg_t | HRM simulator configuration structure |
ant_hrm_simulator_t | HRM simulator structure |
ant_request_controller_t | ANT request controller structure |
ant_sdm_common_data_t | Data structure for SDM common data |
ant_sdm_disp_cb_t | SDM Display control block |
ant_sdm_disp_config_t | SDM Display configuration structure |
ant_sdm_page1_data_t | Data structure for SDM data page 1 |
ant_sdm_page22_data_t | Data structure for SDM data page 22 |
ant_sdm_page2_data_t | Data structure for SDM data page 2 |
ant_sdm_page3_data_t | Data structure for SDM data page 3 |
ant_sdm_profile_s | SDM profile structure |
ant_sdm_sens_cb_t | SDM Sensor control block |
ant_sdm_sens_config_t | SDM Sensor configuration structure |
ant_sdm_simulator_cb_t | SDM simulator control block structure |
ant_sdm_simulator_cfg_t | SDM simulator configuration structure |
ant_sdm_simulator_t | SDM simulator structure |
ant_search_config_t | ANT search configuration structure |
antfs_beacon_status_byte1_t | ANT-FS beacon status |
antfs_dir_header_t | ANT-FS directory header |
antfs_dir_struct_t | ANT-FS directory entry |
antfs_event_return_t | ANT-FS <-> application event communication object |
antfs_params_t | ANT-FS parameters |
antfs_request_info_t | ANT-FS download/upload request context |
app_button_cfg_t | Button configuration structure |
app_fifo_t | A FIFO instance structure |
app_gpiote_user_pin_config_t | Single pin configuration |
app_pwm_config_t | PWM configuration structure used for initialization |
app_pwm_t | PWM instance structure |
app_sdc_config_t | SDC configuration structure |
app_sdc_info_t | SDC information structure |
app_timer_event_t | Structure passed to app_scheduler |
app_timer_t | |
app_uart_buffers_t | UART buffer for transmitting/receiving data |
app_uart_comm_params_t | UART communication structure holding configuration settings for the peripheral |
app_uart_evt_t | Struct containing events from the UART module |
app_uart_stream_comm_params_t | UART communication structure holding configuration settings for the peripheral |
app_usbd_audio_ac_iface_header_desc_t | Audio class control interface header descriptor |
app_usbd_audio_as_endpoint_desc_t | Audio class audio endpoint descriptor |
app_usbd_audio_as_format_type_one_desc_t | Audio class audio streaming format type I descriptor |
app_usbd_audio_as_format_type_three_desc_t | Audio class audio streaming format type III descriptor |
app_usbd_audio_as_format_type_two_desc_t | Audio class audio streaming format type II descriptor |
app_usbd_audio_as_iface_desc_t | Audio class audio streaming interface descriptor |
app_usbd_audio_ctx_t | Audio class context |
app_usbd_audio_feature_unit_desc_t | Audio class feature unit descriptor |
app_usbd_audio_input_terminal_desc_t | Audio class input terminal descriptor |
app_usbd_audio_inst_t | Audio class part of class instance data |
app_usbd_audio_output_terminal_desc_t | Audio class output terminal descriptor |
app_usbd_audio_req_t | Audio class specific request handled via control endpoint |
app_usbd_audio_subclass_desc_t | Audio subclass descriptor |
app_usbd_audio_t | Audio class instance type |
app_usbd_cdc_acm_ctx_t | CDC ACM class context |
app_usbd_cdc_acm_inst_t | CDC ACM class part of class instance data |
app_usbd_cdc_acm_notify_t | CDC ACM serial state class notify |
app_usbd_cdc_acm_req_t | CDC ACM class specific request handled via control endpoint |
app_usbd_cdc_acm_t | CDC ACM class instance type |
app_usbd_cdc_desc_acm_t | CDC ACM Functional Descriptor |
app_usbd_cdc_desc_call_mgmt_t | CDC Call Management Functional Descriptor |
app_usbd_cdc_desc_country_sel_t | Country Selection Functional Descriptor |
app_usbd_cdc_desc_header_t | Header Functional Descriptor |
app_usbd_cdc_desc_union_t | Union Functional Descriptor |
app_usbd_cdc_line_coding_t | CDC line coding structure |
app_usbd_cdc_notify_t | Notification sent via CDC COMM endpoint |
app_usbd_class_data_t | Instance variable data |
app_usbd_class_descriptor_ctx_t | Class descriptor context |
app_usbd_class_descriptor_state_t | Class descriptor state |
app_usbd_class_ep_conf_t | Endpoint configuration |
app_usbd_class_iface_conf_t | Interface configuration |
app_usbd_class_inst_s | The instance structure itself |
app_usbd_class_inst_t | |
app_usbd_class_methods_t | Class interface function set |
app_usbd_complex_evt_t | Complex event variable type |
app_usbd_config_t | Configuration passed to app_usbd_init |
app_usbd_core_setup_data_handler_desc_t | Variable type used to register EP0 transfer handler |
app_usbd_descriptor_configuration_t | Configuration descriptor |
app_usbd_descriptor_device_t | Device descriptor |
app_usbd_descriptor_ep_t | Endpoint descriptor |
app_usbd_descriptor_header_t | Common descriptor header |
app_usbd_descriptor_iad_t | Interface association descriptor |
app_usbd_descriptor_iface_t | Interface descriptor |
app_usbd_descriptor_string0_t | Raw descriptor - String descriptor zero |
app_usbd_descriptor_string_t | Raw descriptor - Any normal string |
app_usbd_dummy_ctx_t | Dummy context |
app_usbd_dummy_inst_t | Dummy part of class instance data |
app_usbd_dummy_t | Dummy class instance type |
app_usbd_evt_t | Specific application event structure |
app_usbd_hid_ctx_t | HID internal context |
app_usbd_hid_descriptor_t | HID descriptor, binary layout |
app_usbd_hid_generic_ctx_t | HID generic context |
app_usbd_hid_generic_inst_t | HID generic part of class instance data |
app_usbd_hid_generic_t | HID generic class instance type |
app_usbd_hid_inst_t | USB HID instance |
app_usbd_hid_kbd_ctx_t | HID keyboard context |
app_usbd_hid_kbd_ctx_internal_s | |
app_usbd_hid_kbd_inst_t | HID keyboard part of class instance data |
app_usbd_hid_kbd_t | HID keyboard class instance type |
app_usbd_hid_methods_t | HID unified interface |
app_usbd_hid_mouse_ctx_t | HID mouse context |
app_usbd_hid_mouse_inst_t | HID mouse part of class instance data |
app_usbd_hid_mouse_t | HID mouse class instance type |
app_usbd_hid_report_buffer_t | HID report buffers |
app_usbd_hid_subclass_desc_t | HID subclass descriptor |
app_usbd_internal_evt_t | Internal event variable type |
app_usbd_msc_cbw_t | Command Block Wrapper (CBW) |
app_usbd_msc_csw_t | Command Status Wrapper (CSW) |
app_usbd_msc_ctx_t | MSC context |
app_usbd_msc_inst_t | MSC part of class instance data |
app_usbd_msc_t | Mass storage class instance type |
app_usbd_nrf_dfu_trigger_ctx_t | Nordic DFU Trigger context |
app_usbd_nrf_dfu_trigger_desc_func_t | Nordic DFU Trigger Functional Descriptor |
app_usbd_nrf_dfu_trigger_inst_t | Nordic DFU Trigger part of class instance data |
app_usbd_nrf_dfu_trigger_nordic_info_t | Nordic custom DFU information |
app_usbd_nrf_dfu_trigger_t | Nordic DFU Trigger class instance type |
app_usbd_scsi_cmd_inquiry_resp_t | Payload of APP_USBD_SCSI_CMD_INQUIRY response |
app_usbd_scsi_cmd_inquiry_t | Payload of APP_USBD_SCSI_CMD_INQUIRY command |
app_usbd_scsi_cmd_modesense10_resp_t | Payload of APP_USBD_SCSI_CMD_MODESENSE10 response |
app_usbd_scsi_cmd_modesense10_t | Payload of APP_USBD_SCSI_CMD_MODESENSE10 command |
app_usbd_scsi_cmd_modesense6_resp_t | Payload of APP_USBD_SCSI_CMD_MODESENSE6 response |
app_usbd_scsi_cmd_modesense6_t | Payload of APP_USBD_SCSI_CMD_MODESENSE6 command |
app_usbd_scsi_cmd_read10_t | Payload of APP_USBD_SCSI_CMD_READ10 command |
app_usbd_scsi_cmd_read6_t | Payload of APP_USBD_SCSI_CMD_READ6 command |
app_usbd_scsi_cmd_readcapacity10_resp_t | Payload of APP_USBD_SCSI_CMD_READCAPACITY10 response |
app_usbd_scsi_cmd_readcapacity10_t | Payload of APP_USBD_SCSI_CMD_READCAPACITY10 command |
app_usbd_scsi_cmd_requestsense_resp_t | Payload of APP_USBD_SCSI_CMD_REQUESTSENSE response |
app_usbd_scsi_cmd_requestsense_t | Payload of APP_USBD_SCSI_CMD_REQUESTSENSE command |
app_usbd_scsi_cmd_write10_t | Payload of APP_USBD_SCSI_CMD_WRITE10 command |
app_usbd_scsi_cmd_write6_t | Payload of APP_USBD_SCSI_CMD_WRITE6 command |
app_usbd_setup_evt_t | Specific application event structure with setup structure included |
app_usbd_setup_t | Internal redefinition of setup structure |
app_usbd_setup_w_t | Universal way to access 16 bit values and its parts |
app_usbd_strings_convert_t | String ID conversion struct |
assert_info_t | Structure containing info about an error of the type NRF_FAULT_ID_SDK_ASSERT |
bh1745_data_t | Measurement result |
bh1745_instance_t | Sensor instance information |
blcm_link_ctx_storage_t | Type of description that is used for registry of all current connections |
ble_add_char_params_t | Add characteristic parameters structure |
ble_add_char_user_desc_t | Characteristic User Descriptor parameters |
ble_add_descr_params_t | Add descriptor parameters structure |
ble_adv_mode_config_t | |
ble_adv_modes_config_t | Options for the different advertisement modes |
ble_advdata_conn_int_t | Connection interval range structure |
ble_advdata_manuf_data_t | Manufacturer specific data structure |
ble_advdata_service_data_t | Service data structure |
ble_advdata_t | Advertising data structure. This structure contains all options and data needed for encoding and setting the advertising data |
ble_advdata_tk_value_t | Security Manager TK value |
ble_advdata_uuid_list_t | UUID list type |
ble_advertising_init_t | Initialization parameters for the Advertising Module |
ble_advertising_t | |
ble_ancs_c_attr_list_t | IOS notification attribute content requested by the application |
ble_ancs_c_attr_t | IOS attribute structure. This type is used for both notification attributes and app attributes |
ble_ancs_c_evt_app_attr_t | |
ble_ancs_c_evt_attr_t | IOS notification attribute structure for incoming attributes |
ble_ancs_c_evt_notif_t | IOS notification structure |
ble_ancs_c_evt_t | ANCS client module event structure |
ble_ancs_c_init_t | Apple Notification client init structure, which contains all options and data needed for initialization of the client |
ble_ancs_c_notif_flags_t | Flags for iOS notifications |
ble_ancs_c_service_t | Structure used for holding the Apple Notification Center Service found during the discovery process |
ble_ancs_c_t | IOS notification structure, which contains various status information for the client |
ble_ancs_parse_sm_t | |
ble_ans_alert_notification_t | Alert Notification structure |
ble_ans_alert_settings_t | Alert Notification Setting structure containing the supported alerts in the service |
ble_ans_c_evt_t | Alert Notification Event structure |
ble_ans_c_init_t | Alert Notification init structure. Contains all options and data needed for the initialization of the client |
ble_ans_c_s | Alert Notification structure. Contains various status information for the client |
ble_ans_c_service_t | Structure for holding information on the Alert Notification Service, if found on the server |
ble_ans_control_point_t | Alert Notification Control Point structure |
ble_bas_c_db_t | Structure containing the handles related to the Battery Service found on the peer |
ble_bas_c_evt_t | Battery Service Client Event structure |
ble_bas_c_init_t | Battery Service Client initialization structure |
ble_bas_c_s | Battery Service Client structure |
ble_bas_evt_t | Battery Service event |
ble_bas_init_t | Battery Service init structure. This contains all options and data needed for initialization of the service |
ble_bas_s | Battery Service structure. This contains various status information for the service |
ble_bps_evt_t | Blood Pressure Service event |
ble_bps_init_t | Blood Pressure Service init structure. This contains all options and data needed for initialization of the service |
ble_bps_meas_s | Blood Pressure Service measurement structure. This contains a Blood Pressure measurement |
ble_bps_s | Blood Pressure Service structure. This contains various status information for the service |
ble_button_t | Structure containing the Button value received from the peer |
ble_cgms_rec_t | CGM Measurement record |
ble_cgms_s | Status information for the CGM Service |
ble_cgms_socp_value_t | Specific Operation Control Point value |
ble_cgms_sst_t | Required data for setting the SST characteristic value |
ble_conn_params_evt_t | Connection Parameters Module event |
ble_conn_params_init_t | Connection Parameters Module init structure. This contains all options and data needed for initialization of the connection parameters negotiation module |
ble_conn_state_conn_handle_list_t | Type used to present a list of conn_handles |
ble_cs_ctrlpt_init_t | Speed and Cadence Control Point init structure. This contains all options and data needed for initialization of the Speed and Cadence Control Point module |
ble_cscs_evt_t | Cycling Speed and Cadence Service event |
ble_cscs_init_t | Cycling Speed and Cadence Service init structure. This contains all options and data needed for initialization of the service |
ble_cscs_meas_s | Cycling Speed and Cadence Service measurement structure. This contains a Cycling Speed and Cadence Service measurement |
ble_cscs_s | Cycling Speed and Cadence Service structure. This contains various status information for the service |
ble_cts_c_evt_t | Current Time Service client event |
ble_cts_c_handles_t | Structure containing the handles related to the Heart Rate Service found on the peer |
ble_cts_c_init_t | Current Time Service client init structure. This structure contains all options and data needed for the initialization of the client |
ble_cts_c_s | Current Time Service client structure. This structure contains status information for the client |
ble_date_time_t | Date and Time structure |
ble_db_discovery_evt_t | Structure containing the event from the DB discovery module to the application |
ble_db_discovery_init_t | DB discovery module initialization struct |
ble_db_discovery_t | Structure for holding the information related to the GATT database at the server |
ble_db_discovery_user_evt_t | Structure containing the pending event |
ble_dfu_buttonless_init_t | Type used to initialize the Secure DFU Buttonless Service |
ble_dfu_buttonless_t | Type holding memory used by Secure DFU Buttonless Service |
ble_dfu_t | DFU Service |
ble_dis_c_char_group_t | Structure describing the group of DIS characteristics with which this module can interact |
ble_dis_c_evt_disc_complete_t | Event structure for BLE_DIS_C_EVT_DISCOVERY_COMPLETE |
ble_dis_c_evt_read_rsp_err_t | Event structure for BLE_DIS_C_EVT_DIS_C_READ_RSP_ERROR |
ble_dis_c_evt_read_rsp_t | Event structure for BLE_DIS_C_EVT_DIS_C_READ_RSP |
ble_dis_c_evt_t | Structure containing the DIS event data received from the peer |
ble_dis_c_init_t | DIS Client initialization structure |
ble_dis_c_s | DIS Client structure |
ble_dis_c_string_t | Response data for string-based DIS characteristics |
ble_dis_init_t | Device Information Service init structure. This contains all possible characteristics needed for initialization of the service |
ble_dis_pnp_id_t | PnP ID parameters |
ble_dis_reg_cert_data_list_t | IEEE 11073-20601 Regulatory Certification Data List Structure |
ble_dis_sys_id_t | System ID parameters |
ble_gap_dev_name_t | Bluetooth Low Energy GAP device name |
ble_gatt_db_char_t | Structure for holding the characteristic and the handle of its CCCD present on a server |
ble_gatt_db_srv_t | Structure for holding information about the service and the characteristics present on a server |
ble_gls_evt_t | Glucose Service event |
ble_gls_init_t | Glucose Service init structure. This contains all options and data needed for initialization of the service |
ble_gls_meas_context_t | Glucose measurement context structure |
ble_gls_meas_t | Glucose Measurement structure. This contains glucose measurement value |
ble_gls_rec_t | Glucose measurement record |
ble_gls_s | Glucose Service structure. This contains various status information for the service |
ble_hids_char_id_t | HID Service characteristic id |
ble_hids_char_sec_t | Security requirements for HID Service characteristic |
ble_hids_client_context_t | HID Host context structure. It keeps information relevant to a single host |
ble_hids_evt_t | HID Service event |
ble_hids_feature_rep_init_t | HID Service Feature Report characteristic init structure. This contains all options and data needed for initialization of one Feature Report characteristic |
ble_hids_hid_information_t | HID Information characteristic value |
ble_hids_init_t | HID Service init structure. This contains all options and data needed for initialization of the service |
ble_hids_inp_rep_init_t | HID Service Input Report characteristic init structure. This contains all options and data needed for initialization of one Input Report characteristic |
ble_hids_outp_rep_init_t | HID Service Output Report characteristic init structure. This contains all options and data needed for initialization of one Output Report characteristic |
ble_hids_rep_char_t | HID Report characteristic structure |
ble_hids_rep_map_init_t | HID Service Report Map characteristic init structure. This contains all options and data needed for initialization of the Report Map characteristic |
ble_hids_s | HID Service structure. This contains various status information for the service |
ble_hrm_t | Structure containing the Heart Rate Measurement received from the peer |
ble_hrs_c_evt_t | Heart Rate Event structure |
ble_hrs_c_init_t | Heart Rate Client initialization structure |
ble_hrs_c_s | Heart Rate Client structure |
ble_hrs_evt_t | Heart Rate Service event |
ble_hrs_init_t | Heart Rate Service init structure. This contains all options and data needed for initialization of the service |
ble_hrs_s | Heart Rate Service structure. This contains various status information for the service |
ble_hts_evt_t | Health Thermometer Service event |
ble_hts_init_t | Health Thermometer Service init structure. This contains all options and data needed for initialization of the service |
ble_hts_meas_s | Health Thermometer Service measurement structure. This contains a Health Thermometer measurement |
ble_hts_s | Health Thermometer Service structure. This contains various status information for the service |
ble_ias_c_evt_t | Immediate Alert Service client event |
ble_ias_c_init_t | IAS Client init structure. Contains all options and data needed for the initialization of the client |
ble_ias_c_s | IAS Client structure. Contains various status information for the client |
ble_ias_client_context_t | Immediate Alert Service client context structure |
ble_ias_evt_t | Immediate Alert Service event |
ble_ias_init_t | Immediate Alert Service init structure. This contains all options and data needed for initialization of the service |
ble_ias_s | Immediate Alert Service structure. This contains various status information for the service |
ble_ipsp_event_param_t | IPSP event parameter |
ble_ipsp_evt_t | IPSP event and associated parameter type |
ble_ipsp_handle_t | IPSP handle |
ble_ipsp_init_t | IPSP initialization structure |
ble_lbs_c_evt_t | LED Button Event structure |
ble_lbs_c_init_t | LED Button Client initialization structure |
ble_lbs_c_s | LED Button Client structure |
ble_lbs_init_t | LED Button Service init structure. This structure contains all options and data needed for initialization of the service |
ble_lbs_s | LED Button Service structure. This structure contains various status information for the service |
ble_lls_evt_t | Link Loss Service event |
ble_lls_init_t | Link Loss Service init structure. This contains all options and data needed for initialization of the service |
ble_lls_s | Link Loss Service structure. This contains various status information for the service |
ble_lncp_evt_t | |
ble_lncp_init_t | |
ble_lncp_mask_t | A mask can be used to temporarily enable and disable features of the Location and Speed characteristic |
ble_lncp_rsp_t | Information included in a control point write response indication |
ble_lncp_s | |
ble_lns_evt_t | Location and Navigation event structure. When an event occurs, the data structures of the module are automatically updated |
ble_lns_init_s | Location and Navigation Service init structure. This structure contains all options and data needed to initialize the service |
ble_lns_loc_speed_s | Location and Speed data structure |
ble_lns_navigation_s | Navigation data structure |
ble_lns_pos_quality_s | Position quality structure |
ble_lns_route_t | Definition of a navigation route |
ble_lns_s | Location and Navigation Service structure. This structure contains various status information for the service |
ble_nus_c_evt_t | Structure containing the NUS event data received from the peer |
ble_nus_c_handles_t | Handles on the connected peer device needed to interact with it |
ble_nus_c_init_t | NUS Client initialization structure |
ble_nus_c_s | NUS Client structure |
ble_nus_client_context_t | Nordic UART Service client context structure |
ble_nus_evt_rx_data_t | Nordic UART Service BLE_NUS_EVT_RX_DATA event data |
ble_nus_evt_t | Nordic UART Service event structure |
ble_nus_init_t | Nordic UART Service initialization structure |
ble_nus_s | Nordic UART Service structure |
ble_ots_evt_t | This structure represents the state of the Object Transfer Service |
ble_ots_init_t | Structure for initializing the OTS |
ble_ots_l2cap_evt_t | L2cap event |
ble_ots_l2cap_init_t | The initialization structure of the l2cap module |
ble_ots_l2cap_s | The structure holding the l2cap connection oriented channels state |
ble_ots_oacp_evt_t | Definition of an OACP event |
ble_ots_oacp_init_t | OACP initialization properties |
ble_ots_oacp_proc_t | |
ble_ots_oacp_s | |
ble_ots_obj_properties_t | Properties of an Object Transfer Service object |
ble_ots_obj_type_t | A structure representing the object type |
ble_ots_object_chars_init_t | Initialization properties of the Object Transfer Service Object characteristics |
ble_ots_object_chars_t | The structure holding the state of the OTS object characteristics |
ble_ots_object_evt_t | The definition of an event from the object characteristics |
ble_ots_object_t | The structure representing one Object Transfer Service object |
ble_ots_s | |
ble_racp_value_t | Record Access Control Point value structure |
ble_rsc_t | Structure containing the Running Speed and Cadence measurement received from the peer |
ble_rscs_c_db_t | Structure containing the handles related to the Running Speed and Cadence Service found on the peer |
ble_rscs_c_evt_t | Running Speed and Cadence Event structure |
ble_rscs_c_init_t | Running Speed and Cadence client initialization structure |
ble_rscs_c_s | Running Speed and Cadence client structure |
ble_rscs_evt_t | Running Speed and Cadence Service event |
ble_rscs_init_t | Running Speed and Cadence Service init structure. This contains all options and data needed for initialization of the service |
ble_rscs_meas_s | Running Speed and Cadence Service measurement structure. This contains a Running Speed and Cadence measurement |
ble_rscs_s | Running Speed and Cadence Service structure. This contains various status information for the service |
ble_sc_ctrlpt_evt_t | Speed and Cadence Control point event |
ble_sc_ctrlpt_resp_t | Speed and Cadence Control Point response indication structure |
ble_sc_ctrlpt_rsp_t | |
ble_sc_ctrlpt_s | Speed and Cadence Control Point structure. This contains various status information for the Speed and Cadence Control Point behavior |
ble_sc_ctrlpt_val_t | |
ble_socp_rsp_t | Specific Operation Control Point response structure |
ble_srv_cccd_security_mode_t | Security settings structure |
ble_srv_report_ref_t | Value of a Report Reference descriptor |
ble_srv_security_mode_t | Security settings structure |
ble_srv_utf8_str_t | UTF-8 string data type |
ble_tps_init_t | TX Power Service init structure. This contains all options and data needed for initialization of the service |
ble_tps_t | TX Power Service structure. This contains various status information for the service |
boot_validation_t | |
bsp_button_event_cfg_t | |
ccs811_alg_data_t | Structure for holding algorithm data |
ccs811_instance_t | Structure holding sensor instance |
cdc_rx_buffer_t | CDC ACM rx transfer buffer |
cli_libuarte_config_t | |
cli_libuarte_internal_cb_t | |
cli_libuarte_internal_s | |
CONCAT_2 | Declare Core instance type |
CRYS_AESCCM_UserContext_t | |
CRYS_CHACHAUserContext_t | |
CRYS_DH_ExpTemp_t | |
CRYS_DH_FipsKat_t | |
CRYS_DH_HybrTemp_t | |
CRYS_DH_Temp_t | |
CRYS_DHKG_CheckTemp_t | |
CRYS_DHKGData_t | |
CRYS_ECDH_TempData_t | |
CRYS_ECDHFipsKatContext_t | |
CRYS_ECDSA_SignUserContext_t | |
CRYS_ECDSA_VerifyUserContext_t | |
CRYS_ECDSAFipsKatContext_t | |
CRYS_ECEDW_TempBuff_t | |
CRYS_ECIES_TempData_t | |
CRYS_ECMONT_ScalrMultTempBuff_t | |
CRYS_ECMONT_TempBuff_t | |
CRYS_ECPKI_BUILD_TempData_t | |
CRYS_ECPKI_Domain_t | |
CRYS_ECPKI_KG_FipsContext_t | |
CRYS_ECPKI_KG_TempData_t | |
CRYS_ECPKI_PointAffine_t | |
CRYS_ECPKI_PrivKey_t | |
CRYS_ECPKI_PublKey_t | |
CRYS_ECPKI_UserPrivKey_t | |
CRYS_ECPKI_UserPublKey_t | |
CRYS_HASHUserContext_t | |
CRYS_HMACUserContext_t | |
CRYS_KDF_OtherInfo_t | |
CRYS_PrngFipsKatCtx_t | |
CRYS_RND_State_t | |
CRYS_RND_WorkBuff_t | |
CRYS_RSAFipsKatContext_t | |
CRYS_RSAKGData_t | |
CRYS_RSAKGFipsContext_t | |
CRYS_RSAPrimeData_t | |
CRYS_RSAPrivUserContext_t | |
CRYS_RSAPubUserContext_t | |
CRYS_RSAUserPrivKey_t | |
CRYS_RSAUserPubKey_t | |
CRYS_SRP_Context_t | |
CRYS_SRP_GroupParam_t | |
CRYSRSAPrivCRTKey_t | |
CRYSRSAPrivKey_t | |
CRYSRSAPrivNonCRTKey_t | |
CRYSRSAPubKey_t | |
current_time_char_t | Data structure for the Current Time characteristic |
day_date_time_t | "Day Date Time" field of the "Exact Time 256" field of the Current Time characteristic |
dfu_boot_validation_t | |
dfu_command_t | |
dfu_hash_t | |
dfu_init_command_t | |
dfu_packet_t | |
dfu_progress_t | |
dfu_signed_command_t | |
drv_rtc_config_t | RTC driver instance configuration structure |
drv_rtc_t | RTC driver instance structure |
ECDSA_SignContext_t | |
ECDSA_VerifyContext_t | |
error_info_t | Structure containing info about an error of the type NRF_FAULT_ID_SDK_ERROR |
es_adv_frame_t | Advertisable frame types that can be passed in to the advertising data during non-connectable slot advertising |
es_adv_timing_evt_t | Eddystone advertisement timing event |
es_adv_timing_resolver_adv_timing_t | Timing parameters for a single slot |
es_adv_timing_resolver_input_t | Input to the timing resolver |
es_adv_timing_resolver_result_t | Results of calculating advertisement delays |
es_eid_config_t | EID configuration |
es_eid_frame_t | EID frame data representation |
es_etlm_frame_t | ETLM frame data representation |
es_flash_beacon_config_t | Beacon configuration |
es_flash_flags_t | Structure for keeping track of which slot has a configuration that must be restored upon reboot |
es_slot_reg_t | Slot registry |
es_slot_t | Slot |
es_tlm_frame_t | TLM frame data representation |
es_uid_frame_t | UID frame data representation |
es_url_frame_t | URL frame data representation |
exact_time_256_t | "Exact Time 256" field of the Current Time characteristic |
fds_evt_t | An FDS event |
fds_find_token_t | A token to keep information about the progress of fds_record_find, fds_record_find_by_key, and fds_record_find_in_file |
fds_flash_record_t | Structure that can be used to read the contents of a record stored in flash |
fds_gc_data_t | |
fds_header_t | The record metadata as stored in flash |
fds_op_t | |
fds_page_t | |
fds_record_desc_t | The record descriptor structure that is used to manipulate records |
fds_record_t | A record to be written to flash |
fds_reserve_token_t | A token to a reserved space in flash, created by fds_reserve |
fds_stat_t | File system statistics |
fds_swap_page_t | |
FONT_CHAR_INFO | Font char information |
FONT_INFO | Font descriptor |
hal_exceptions_dump_t | This structure is put into dump monitor port and holds values of said registers when exception has happen |
hal_exceptions_status_registers_t | This structure holds values of fault status registers |
hal_uart_config_t | HAL UART configuration structure |
hal_uart_descriptor_t | This structure defines the UART module operation |
HardFault_stack | Contents of the stack |
hash_data_from_host | To specify the data coming from the host for hashing |
hash_data_in_optiga | To specify the data object for hashing |
hci_slip_evt_t | Structure containing an event from the SLIP layer |
hci_transport_evt_t | Struct containing events from the Transport layer |
hci_transport_ioctl_cmd_t | |
hrs_db_t | Structure containing the handles related to the Heart Rate Service found on the peer |
hts221_calib_t | Structure holding calibration information |
hts221_instance_t | Structure holding sensor instance |
ieee_float16_t | SFLOAT format (IEEE-11073 16-bit FLOAT, defined as a 16-bit vlue with 12-bit mantissa and 4-bit exponent |
ieee_float32_t | FLOAT format (IEEE-11073 32-bit FLOAT, defined as a 32-bit value with a 24-bit mantissa and an 8-bit exponent |
ifx_i2c_context | IFX I2C context structure |
ifx_i2c_dl | Datalink layer structure |
ifx_i2c_pl | Physical layer structure |
ifx_i2c_tl | Transport layer structure |
key_from_opitga | To specify the OID which holds the shared secret |
lbs_db_t | Structure containing the handles related to the LED Button Service found on the peer |
lcd_cb_t | LCD instance control block |
led_sb_init_params_t | Structure holding the initialization parameters |
lis2dh12_data_t | Structure containing accelerometer data |
lis2dh12_instance_t | Structure holding sensor instance |
low_power_pwm_config_t | Structure holding the initialization parameters |
lps22hb_data_t | Pressure and temperature output data |
lps22hb_instance_t | Structure holding sensor instance |
lps22hb_raw_data_t | Raw pressure and temperature data |
mac_abstract_req_t | MAC request descriptor |
mac_addr_t | MAC ADDRESS |
mac_capability_t | Capability information field |
mac_device_descr_t | DeviceDescriptor as described in Table 93 |
mac_gts_characteristics_t | MAC GTS characteristics (not packed) |
mac_key_descr_t | KeyDescriptor as described in Table 89 |
mac_key_device_descr_t | KeyDeviceDescriptor as described in Table 91 |
mac_key_id_lookup_descr_t | KeyIdLookupDescriptor as described in Table 94 |
mac_key_usage_descr_t | KeyUsageDescriptor as described in Table 90 |
mac_pan_descriptor_t | PAN Descriptor structure |
mac_payload_descriptor_t | Payload descriptor |
mac_pend_addr_spec_t | Pending Address Specification |
mac_pending_addr_list_t | List of pending addresses Short addresses are at the top of the table |
mac_scheduler_mem_t | Scheduler memory |
mac_security_level_descr_t | SecurityLevelDescriptor as described in Table 93 |
mac_superframe_spec_t | Superframe specification structure |
mac_table_item_t | Due to processing algorithm this field MUST be the first inside a table or list |
mac_table_t | Abstract type to work with growing tables such as some of MAC security attributes |
mac_tx_options_t | TX options for MAC data transmission |
max9850_config_t | MAX9850 configuration |
max9850_regmap_t | Internal MAX9850 register map |
mcp4725_pins_config_t | |
mcps_data_conf_t | MCPS-DATA.confirm |
mcps_data_ind_private_t | Private information passed with MCPS-DATA.indication. Not covered by the standard |
mcps_data_ind_t | MCPS-DATA.indication |
mcps_data_req_t | MCPS-DATA.request |
mcps_purge_conf_t | MCPS-PURGE.confirm |
mcps_purge_req_t | MCPS-PURGE.request |
mlme_beacon_notify_ind_t | MLME-BEACON-NOTIFY.indication parameters |
mlme_comm_status_ind_t | MLME-COMM-STATUS.indication |
mlme_disassociate_conf_t | MLME-DISASSOCIATE.confirm |
mlme_disassociate_ind_t | MLME-DISASSOCIATE.indication |
mlme_disassociate_req_t | MLME-DISASSOCIATE.request |
mlme_get_conf_t | MLME-GET.confirm |
mlme_get_req_t | MLME-GET.request |
mlme_gts_conf_t | MLME-GTS.confirm |
mlme_gts_ind_t | MLME-GTS.indication |
mlme_gts_req_t | MLME-GTS.request |
mlme_orphan_ind_t | MLME-ORPHAN.indication |
mlme_orphan_resp_t | MLME-ORPHAN.response |
mlme_poll_conf_t | MLME-POLL.confirm |
mlme_poll_ind_t | MLME-Poll.indication |
mlme_poll_req_t | MLME-POLL.request |
mlme_reset_conf_t | MLME-Reset.confirm |
mlme_reset_req_t | MLME-RESET.request |
mlme_rx_enable_conf_t | MLME-RX-ENABLE.confirm |
mlme_rx_enable_req_t | MLME-RX-ENABLE.request |
mlme_scan_conf_t | MLME-SCAN.confirm |
mlme_scan_req_t | MLME-SCAN.request |
mlme_set_conf_t | MLME-SET.confirm |
mlme_set_req_t | MLME-SET.request |
mlme_start_conf_t | MLME-Start.confirm |
mlme_start_req_t | MLME-START.request |
mlme_sync_loss_ind_t | MLME-SYNC-LOSS.indication |
my_evt | |
nfc_a_tag_info | Basic information about detected NFC-A tag |
nfc_ac_rec_data_ref_t | Carrier Data Reference and Auxiliary Data Reference descriptor |
nfc_ac_rec_payload_desc_t | Alternative Carrier record payload descriptor |
nfc_ble_oob_pairing_data_t | BLE Advertising data that is relevant for OOB pairing |
nfc_hs_rec_payload_desc_t | Handover Select record payload descriptor |
nfc_ndef_bin_payload_desc_t | Binary data descriptor containing the payload for the record |
nfc_ndef_msg_desc_t | NDEF message descriptor |
nfc_ndef_parser_memo_desc_t | Type for holding descriptors that are used by the NDEF parser |
nfc_ndef_record_desc_t | NDEF record descriptor |
nfc_t4t_apdu_data_t | APDU data field descriptor |
nfc_t4t_capability_container_t | Descriptor for the Capability Container (CC) file of Type 4 Tag |
nfc_t4t_comm_apdu_t | Command Application Protocol Data Unit (C-APDU) descriptor |
nfc_t4t_file_control_val_t | Extended NDEF/NDEF/Proprietary File Control Value descriptor |
nfc_t4t_file_t | File content descriptor |
nfc_t4t_resp_apdu_t | Response Application Protocol Data Unit (R-APDU) descriptor |
nfc_t4t_tlv_block_t | File Control TLV block descriptor |
nfc_text_rec_payload_desc_t | Text record payload descriptor |
notification_t | |
nrf_adc_config_t | Analog-to-digital converter configuration |
nrf_atfifo_item_put_s | FIFO write operation item context |
nrf_atfifo_postag_pos_s | Read and write position structure |
nrf_atfifo_postag_u | End data index tag |
nrf_atfifo_rcontext_s | FIFO read operation item context |
nrf_atfifo_s | The FIFO instance |
nrf_balloc_cb_t | Block memory allocator control block |
nrf_balloc_t | Block memory allocator pool instance. The pool is made of elements of the same size |
nrf_ble_bms_auth_code_t | Received authorization codes |
nrf_ble_bms_bond_cbs_t | BMS bond management callbacks |
nrf_ble_bms_ctrlpt_t | BMS control points |
nrf_ble_bms_evt_t | BMS events |
nrf_ble_bms_features_t | Supported features |
nrf_ble_bms_init_t | BMS initialization structure that contains all information needed to initialize the service |
nrf_ble_bms_s | Status information for the service |
nrf_ble_cgm_status_t | Status of the CGM measurement |
nrf_ble_cgms_calib_t | Calibration value |
nrf_ble_cgms_char_handler_t | Handles related to CGM characteristics |
nrf_ble_cgms_evt_t | CGM Service event |
nrf_ble_cgms_feature_t | Features supported by the CGM Service |
nrf_ble_cgms_init_t | CGM Service initialization structure that contains all options and data needed for initializing the service |
nrf_ble_cgms_meas_t | CGM measurement |
nrf_ble_cgms_racp_t | Record Access Control Point transaction data |
nrf_ble_cgms_sensor_annunc_t | CGM Measurement Sensor Status Annunciation |
nrf_ble_escs_broadcast_cap_t | Data fields in the Broadcast Capabilities characteristic |
nrf_ble_escs_eid_id_key_t | EID Identity Key characteristic |
nrf_ble_escs_init_params_t | Eddystone Configuration Service initialization parameters (corresponding to required characteristics) |
nrf_ble_escs_init_t | Eddystone Configuration Service initialization structure |
nrf_ble_escs_lock_state_t | Lock State characteristic |
nrf_ble_escs_lock_state_write_t | Write data fields of the Lock State characteristic |
nrf_ble_escs_public_ecdh_key_t | Public ECDH Key characteristic |
nrf_ble_escs_remain_conntbl_t | Unlock characteristic (read/write) |
nrf_ble_escs_s | |
nrf_ble_escs_unlock_t | Unlock characteristic (read/write) |
nrf_ble_gatt_evt_t | GATT module event |
nrf_ble_gatt_link_t | GATT information for each connection |
nrf_ble_gatt_s | GATT structure that contains status information for the GATT module |
nrf_ble_gatts_c_evt_t | Structure containing the event from the Service Changed client module to the application |
nrf_ble_gatts_c_init_t | Initialization parameters. These must be supplied when calling nrf_ble_gatts_c_init |
nrf_ble_gatts_c_t | Structure for holding the information related to the Service Changed indication at the server |
nrf_ble_gq_gattc_read_t | Structure used to describe NRF_BLE_GQ_REQ_GATTC_READ request type |
nrf_ble_gq_gattc_srv_discovery_t | Structure used to describe NRF_BLE_GQ_REQ_SRV_DISCOVERY request type |
nrf_ble_gq_req_error_handler_t | Structure used to handle SoftDevice error |
nrf_ble_gq_req_t | Structure used to describe BLE GATT request |
nrf_ble_gq_t | Descriptor for the BLE GATT Queue instance |
nrf_ble_ots_c_evt_t | Structure containing the event from the Object Transfer client module to the application |
nrf_ble_ots_c_feature_t | Structure to hold the features of a server |
nrf_ble_ots_c_init_t | Initialization parameters. These must be supplied when calling nrf_ble_ots_c_init |
nrf_ble_ots_c_oacp_response_t | Structure to hold responses received when writing to the Object Action Control Point on the server |
nrf_ble_ots_c_obj_properties_t | Properties of an Object Transfer Service object |
nrf_ble_ots_c_obj_size | Structure to hold the size of the object on the server when read from the Object Size characteristic on the server |
nrf_ble_ots_c_service_t | Structure for holding the Object Transfer Service found during the discovery process |
nrf_ble_ots_c_t | Structure for holding the information related to the Object Transfer Service |
nrf_ble_qwr_evt_t | Queued Writes module events |
nrf_ble_qwr_init_t | Queued Writes init structure |
nrf_ble_qwr_t | Queued Writes structure |
nrf_ble_scan_addr_filter_t | |
nrf_ble_scan_appearance_filter_t | |
nrf_ble_scan_evt_connected_t | Event structure for NRF_BLE_SCAN_EVT_CONNECTED |
nrf_ble_scan_evt_connecting_err_t | Event structure for NRF_BLE_SCAN_EVT_CONNECTING_ERROR |
nrf_ble_scan_evt_filter_match_t | Event structure for NRF_BLE_SCAN_EVT_FILTER_MATCH |
nrf_ble_scan_filter_match | Structure for setting the filter status |
nrf_ble_scan_filters_t | Filters data |
nrf_ble_scan_init_t | Structure for Scanning Module initialization |
nrf_ble_scan_name_filter_t | |
nrf_ble_scan_short_name_filter_t | |
nrf_ble_scan_short_name_t | |
nrf_ble_scan_t | Scan module instance. Options for the different scanning modes |
nrf_ble_scan_uuid_filter_t | |
nrf_block_dev_empty_config_t | EMPTY block device config |
nrf_block_dev_empty_t | EMPTY block device |
nrf_block_dev_empty_work_t | Work structure of EMPTY block device |
nrf_block_dev_event_t | Block device event |
nrf_block_dev_geometry_t | Block device geometry |
nrf_block_dev_info_strings_t | Block device information strings |
nrf_block_dev_qspi_config_t | QSPI block device config |
nrf_block_dev_qspi_t | QSPI block device |
nrf_block_dev_qspi_work_t | Work structure of QSPI block device |
nrf_block_dev_ram_config_t | Ram block device config |
nrf_block_dev_ram_t | Ram block device |
nrf_block_dev_ram_work_t | Work structure of RAM block device |
nrf_block_dev_s | Block device API |
nrf_block_dev_ops_s | |
nrf_block_dev_sdc_config_t | SDC block device config |
nrf_block_dev_sdc_t | SDC block device |
nrf_block_dev_sdc_work_t | Work structure of SDC block device |
nrf_block_req_t | Block device request descriptor item |
nrf_ccm_config_t | CCM configuration |
nrf_cli | CLI instance internals |
nrf_cli_ble_uart_config_t | |
nrf_cli_ble_uart_internal_cb_t | |
nrf_cli_ble_uart_internal_s | |
nrf_cli_cdc_acm_internal_cb_t | |
nrf_cli_cdc_acm_internal_t | |
nrf_cli_cmd_entry | CLI command descriptor |
nrf_cli_ctx_t | CLI instance context |
nrf_cli_flag_t | |
nrf_cli_getopt_option | Option descriptor |
nrf_cli_internal_t | |
nrf_cli_log_backend_t | |
nrf_cli_multiline_cons_t | |
nrf_cli_rtt_internal_cb_t | CLI RTT transport control block structure |
nrf_cli_rtt_internal_t | CLI RTT transport instance structure |
nrf_cli_static_entry | CLI static command descriptor |
nrf_cli_transport_api_t | Unified CLI transport interface |
nrf_cli_transport_s | |
nrf_cli_uart_internal_cb_t | |
nrf_cli_uart_internal_s | |
nrf_cli_vt100_colors_t | |
nrf_cli_vt100_ctx_t | |
nrf_comp_ref_conf_t | COMP reference configuration |
nrf_comp_th_t | COMP THDOWN and THUP values that are used to calculate the threshold voltages VDOWN and VUP |
nrf_crypto_aead_info_t | |
nrf_crypto_aead_internal_context_t | |
nrf_crypto_aes_info_t | |
nrf_crypto_aes_internal_context_t | |
nrf_crypto_backend_aead_context_t | |
nrf_crypto_backend_aes_context_t | |
nrf_crypto_backend_aes_ctx_t | |
nrf_crypto_backend_hash_context_t | |
nrf_crypto_backend_hmac_context_t | |
nrf_crypto_backend_info_t | |
nrf_crypto_backend_no_iv_aes_ctx_t | |
nrf_crypto_backend_rng_temp_buffer_t | |
nrf_crypto_ecc_curve_info_s | Structure holding information on a specific curve |
nrf_crypto_ecc_key_pair_generate_context_t | Union holding a context for a key pair generation |
nrf_crypto_ecc_private_key_t | Union holding representation of a private key for any curve type |
nrf_crypto_ecc_public_key_calculate_context_t | Union holding a context for a public key calculation |
nrf_crypto_ecc_public_key_t | Union holding representation of a public key for any curve type |
nrf_crypto_ecdh_context_t | Union holding a context for ECDH computation |
nrf_crypto_ecdsa_sign_context_t | Union holding a context for ECDSA hash sign |
nrf_crypto_ecdsa_verify_context_t | Union holding a context for ECDSA hash verify |
nrf_crypto_hash_info_t | |
nrf_crypto_hash_internal_context_t | |
nrf_crypto_hmac_info_t | |
nrf_crypto_hmac_internal_context_t | |
nrf_crypto_rng_internal_context_t | |
nrf_csense_evt_param_t | Event data union for nrf_csense events |
nrf_csense_evt_t | Structure with event parameters |
nrf_csense_slider_evt_t | Structure with slider event data including the measured step |
nrf_dfu_adv_name_t | |
nrf_dfu_bank_t | Description of a single bank |
nrf_dfu_peer_data_t | |
nrf_dfu_request_create_t | NRF_DFU_OP_OBJECT_CREATE request details |
nrf_dfu_request_firmware_t | NRF_DFU_OP_FIRMWARE_VERSION request details |
nrf_dfu_request_mtu_t | NRF_DFU_OP_MTU_GET request details |
nrf_dfu_request_ping_t | NRF_DFU_OP_PING request details |
nrf_dfu_request_prn_t | NRF_DFU_OP_RECEIPT_NOTIF_SET request details |
nrf_dfu_request_select_t | NRF_DFU_OP_OBJECT_SELECT request details |
nrf_dfu_request_t | DFU request |
nrf_dfu_request_write_t | NRF_DFU_OP_OBJECT_WRITE request details |
nrf_dfu_response_crc_t | NRF_DFU_OP_CRC_GET response details |
nrf_dfu_response_create_t | NRF_DFU_OP_OBJECT_CREATE response details |
nrf_dfu_response_firmware_t | NRF_DFU_OP_FIRMWARE_VERSION response details |
nrf_dfu_response_hardware_t | NRF_DFU_OP_HARDWARE_VERSION response details |
nrf_dfu_response_mtu_t | NRF_DFU_OP_MTU_GET response details |
nrf_dfu_response_ping_t | NRF_DFU_OP_PING response details |
nrf_dfu_response_protocol_t | NRF_DFU_OP_PROTOCOL_VERSION response details |
nrf_dfu_response_select_t | NRF_DFU_OP_OBJECT_SELECT response details |
nrf_dfu_response_t | DFU response message |
nrf_dfu_response_write_t | NRF_DFU_OP_OBJECT_WRITE response details |
nrf_dfu_serial_t | DFU serial transport layer state |
nrf_dfu_settings_t | DFU settings for application and bank data |
nrf_dfu_transport_s | DFU transport registration |
nrf_drv_clock_handler_item_s | |
nrf_drv_csense_config_t | Module initializing structure |
nrf_drv_csense_evt_t | Structure holding event parameters |
nrf_drv_spi_config_t | SPI master driver instance configuration structure |
nrf_drv_spi_evt_t | |
nrf_drv_spi_t | SPI master driver instance data structure |
nrf_drv_spi_xfer_desc_t | Single transfer descriptor structure |
nrf_drv_twi_config_t | Structure for the TWI master driver instance configuration |
nrf_drv_twi_evt_t | Structure for a TWI event |
nrf_drv_twi_t | Structure for the TWI master driver instance |
nrf_drv_twi_xfer_desc_t | Structure for a TWI transfer descriptor |
nrf_drv_uart_config_t | Structure for UART configuration |
nrf_drv_uart_error_evt_t | Structure for UART error event |
nrf_drv_uart_event_t | Structure for UART event |
nrf_drv_uart_t | Structure for the UART driver instance |
nrf_drv_uart_xfer_evt_t | Structure for UART transfer completion event |
nrf_esb_config_t | Main configuration structure for the module |
nrf_esb_evt_t | Enhanced ShockBurst event |
nrf_esb_payload_t | Enhanced ShockBurst payload |
nrf_fstorage_api_s | Functions provided by the API implementation |
nrf_fstorage_evt_t | An fstorage event |
nrf_fstorage_info_t | Information about the implementation and the flash peripheral |
nrf_fstorage_t | An fstorage instance |
nrf_gfx_circle_t | GFX circle object structure |
nrf_gfx_line_t | GFX line object structure |
nrf_gfx_point_t | GFX point object structure |
nrf_gfx_rect_t | GFX rectangle object structure |
nrf_gzll_device_tx_info_t | Data structure containing information about the last packet transmission |
nrf_gzll_host_rx_info_t | Data structure containing information about the last packet received |
nrf_gzll_pa_lna_cfg_t | Data structure holding external front end control configuration |
nrf_gzll_tx_statistics_t | |
nrf_lcd_t | LCD instance type |
nrf_libuarte_app_timer_ctrl_blk_t | |
nrf_libuarte_async_config_t | Structure for libuarte async configuration |
nrf_libuarte_async_ctrl_blk_t | Nrf_libuarte_async control block (placed in RAM) |
nrf_libuarte_async_data_t | Structure for libuarte async transfer completion event |
nrf_libuarte_async_evt_t | Structure for libuarte error event |
nrf_libuarte_async_overrun_err_evt_t | Structu for software error event |
nrf_libuarte_async_t | Nrf_libuarte_async instance structure (placed in ROM) |
nrf_libuarte_drv_config_t | |
nrf_libuarte_drv_ctrl_blk_t | |
nrf_libuarte_drv_data_t | |
nrf_libuarte_drv_evt_t | |
nrf_libuarte_drv_overrun_err_evt_t | |
nrf_libuarte_drv_t | |
nrf_log_backend_api_t | Logger backend API |
nrf_log_backend_cb_t | Logger backend control block |
nrf_log_backend_crashlog_t | Crashlog logger backend structure |
nrf_log_backend_flashlog_t | Flashlog logger backend structure |
nrf_log_backend_rtt_t | |
nrf_log_backend_s | Logger backend structure |
nrf_log_backend_uart_t | |
nrf_log_generic_header_t | |
nrf_log_header_t | |
nrf_log_hexdump_header_t | |
nrf_log_main_header_t | |
nrf_log_module_const_data_t | Structure holding constant data associated with a module or instance |
nrf_log_module_dynamic_data_t | Structure holding dynamic data associated with a module |
nrf_log_module_filter_data_t | Structure holding dynamic filters associated with a module or instance if filtering is enabled (NRF_LOG_FILTERS_ENABLED) |
nrf_log_std_header_t | |
nrf_log_str_formatter_entry_params_t | |
nrf_lpcomp_config_t | LPCOMP configuration |
nrf_pwm_sequence_t | Structure for defining a sequence of PWM duty cycles |
nrf_pwm_values_grouped_t | Structure for defining duty cycle values for a sequence loaded in NRF_PWM_LOAD_GROUPED mode |
nrf_pwm_values_individual_t | Structure for defining duty cycle values for a sequence loaded in NRF_PWM_LOAD_INDIVIDUAL mode |
nrf_pwm_values_t | Union grouping pointers to arrays of duty cycle values applicable to various loading modes |
nrf_pwm_values_wave_form_t | Structure for defining duty cycle values for a sequence loaded in NRF_PWM_LOAD_WAVE_FORM mode |
nrf_qspi_addrconfig_conf_t | Addressing mode register configuration. See nrf_qspi_addrconfig_set |
nrf_qspi_cinstr_conf_t | Custom instruction configuration |
nrf_qspi_phy_conf_t | QSPI physical interface configuration |
nrf_qspi_pins_t | Pin configuration |
nrf_qspi_prot_conf_t | Structure with QSPI protocol interface configuration |
nrf_queue_cb_t | Queue control block |
nrf_queue_t | Instance of the queue |
nrf_radio_packet_conf_t | Packet configuration |
nrf_ringbuf_cb_t | Ring buffer instance control block |
nrf_ringbuf_t | Ring buffer instance structure |
nrf_saadc_channel_config_t | Analog-to-digital converter channel configuration structure |
nrf_saadc_config_t | Analog-to-digital converter configuration structure |
nrf_sdh_ant_evt_observer_t | ANT event observer |
nrf_sdh_ble_evt_observer_t | BLE event observer |
nrf_sdh_req_observer_t | SoftDevice Handler state request observer |
nrf_sdh_soc_evt_observer_t | SoC event observer |
nrf_sdh_stack_observer_t | SoftDevice stack event observer |
nrf_sdh_state_observer_t | SoftDevice Handler state observer |
nrf_section_iter_t | Section iterator structure |
nrf_section_set_t | Set of the sections description structure |
nrf_section_t | Single section description structure |
nrf_serial_flash_params_t | Serial flash memory parameters |
nrf_sortlist_cb_t | Sorted list instance control block |
nrf_sortlist_item_s | A structure for item in the sorted list |
nrf_sortlist_t | Structure for sorted list instance |
nrf_spi_mngr_cb_t | SPI instance control block |
nrf_spi_mngr_t | SPI transaction manager instance |
nrf_spi_mngr_transaction_t | SPI transaction descriptor |
nrf_spi_mngr_transfer_t | SPI transfer descriptor |
nrf_svc_func_reg_t | Type holding the SVC number, SVCI number, and the pointer to the corresponding handler function |
nrf_twi_mngr_cb_t | TWI instance control block |
nrf_twi_mngr_t | TWI transaction manager instance |
nrf_twi_mngr_transaction_t | TWI transaction descriptor |
nrf_twi_mngr_transfer_t | TWI transfer descriptor |
nrf_twi_sensor_cmd_t | Union for sensor commands. Needed in buffer definition |
nrf_twi_sensor_read_cmd_t | Struct describing sensor read command |
nrf_twi_sensor_t | Structure holding sensor instance |
nrf_twi_sensor_write_cmd_t | Struct describing sensor write command |
nrfx_adc_channel_s | ADC channel |
nrfx_adc_config_t | ADC configuration |
nrfx_adc_done_evt_t | ADC driver DONE event structure |
nrfx_adc_evt_t | ADC driver event |
nrfx_adc_sample_evt_t | SAMPLE event structure |
nrfx_comp_config_t | COMP configuration |
nrfx_gpiote_in_config_t | Input pin configuration |
nrfx_gpiote_out_config_t | Output pin configuration |
nrfx_i2s_buffers_t | I2S driver buffers structure |
nrfx_i2s_config_t | I2S driver configuration structure |
nrfx_lpcomp_config_t | LPCOMP configuration |
nrfx_nfct_config_t | NFCT driver configuration structure |
nrfx_nfct_data_desc_t | NFCT driver RX/TX buffer descriptor |
nrfx_nfct_evt_error_t | Structure used to describe the NRFX_NFCT_EVT_ERROR event type |
nrfx_nfct_evt_rx_frameend_t | Structure used to describe the NRFX_NFCT_EVT_RX_FRAMEEND event type |
nrfx_nfct_evt_t | NFCT driver event |
nrfx_nfct_evt_tx_framestart_t | Structure used to describe the NRFX_NFCT_EVT_TX_FRAMESTART event type |
nrfx_nfct_nfcid1_t | NFCID1 descriptor |
nrfx_nfct_param_t | NFCT driver parameter descriptor |
nrfx_pdm_config_t | PDM interface driver configuration structure |
nrfx_pdm_evt_t | PDM event structure |
nrfx_power_config_t | General power configuration |
nrfx_power_pofwarn_config_t | The configuration for power failure comparator |
nrfx_power_sleepevt_config_t | The configuration of sleep event processing |
nrfx_power_usbevt_config_t | The configuration of the USB-related power events |
nrfx_pwm_config_t | PWM driver configuration structure |
nrfx_pwm_t | PWM driver instance data structure |
nrfx_qdec_config_t | QDEC configuration structure |
nrfx_qdec_event_t | QDEC event handler structure |
nrfx_qdec_report_data_evt_t | QDEC report event data |
nrfx_qdec_sample_data_evt_t | QDEC sample event data |
nrfx_qspi_config_t | QSPI driver instance configuration structure |
nrfx_rng_config_t | Struct for RNG configuration |
nrfx_rtc_config_t | RTC driver instance configuration structure |
nrfx_rtc_t | RTC driver instance structure |
nrfx_saadc_adv_config_t | SAADC driver advanced mode configuration structure |
nrfx_saadc_channel_t | SAADC channel configuration structure |
nrfx_saadc_config_t | SAADC driver configuration structure |
nrfx_saadc_done_evt_t | SAADC driver done event data |
nrfx_saadc_evt_t | SAADC driver event structure |
nrfx_saadc_limit_evt_t | SAADC driver limit event data |
nrfx_spi_config_t | Configuration structure of the SPI master driver instance |
nrfx_spi_evt_t | SPI master event description with transmission details |
nrfx_spi_t | Data structure of the Serial Peripheral Interface master (SPI) driver instance |
nrfx_spi_xfer_desc_t | Single transfer descriptor structure |
nrfx_spim_config_t | Configuration structure of the SPIM driver instance |
nrfx_spim_evt_t | SPIM event description with transmission details |
nrfx_spim_t | Data structure of the Serial Peripheral Interface Master with EasyDMA (SPIM) driver instance |
nrfx_spim_xfer_desc_t | Single transfer descriptor structure |
nrfx_spis_config_t | SPI peripheral device configuration data |
nrfx_spis_evt_t | SPI slave driver event structure |
nrfx_spis_t | Data structure for the Serial Peripheral Interface Slave with EasyDMA (SPIS) driver instance |
nrfx_systick_state_t | The value type that holds the SysTick state |
nrfx_temp_config_t | Structure for TEMP configuration |
nrfx_timer_config_t | The configuration structure of the timer driver instance |
nrfx_timer_t | Timer driver instance data structure |
nrfx_twi_config_t | Structure for the configuration of the TWI master driver instance |
nrfx_twi_evt_t | Structure for a TWI event |
nrfx_twi_t | Structure for the TWI master driver instance |
nrfx_twi_xfer_desc_t | Structure for a TWI transfer descriptor |
nrfx_twim_config_t | Structure for the TWI master driver instance configuration |
nrfx_twim_evt_t | Structure for a TWI event |
nrfx_twim_t | Structure for the TWI master driver instance |
nrfx_twim_xfer_desc_t | Structure for a TWI transfer descriptor |
nrfx_twis_config_t | Structure for TWIS configuration |
nrfx_twis_evt_t | TWIS driver event structure |
nrfx_twis_t | TWIS driver instance data structure |
nrfx_uart_config_t | Structure for the UART configuration |
nrfx_uart_error_evt_t | Structure for the UART error event |
nrfx_uart_event_t | Structure for the UART event |
nrfx_uart_t | Data structure of the UART driver instance |
nrfx_uart_xfer_evt_t | Structure for the UART transfer completion event |
nrfx_uarte_config_t | Structure for the UARTE configuration |
nrfx_uarte_error_evt_t | Structure for UARTE error event |
nrfx_uarte_event_t | Structure for UARTE event |
nrfx_uarte_t | Structure for the UARTE driver instance |
nrfx_uarte_xfer_evt_t | Structure for the UARTE transfer completion event |
nrfx_usbd_data_ptr_t | Universal data pointer |
nrfx_usbd_ep_transfer_t | Structure to be filled with information about the next transfer |
nrfx_usbd_evt_t | Event structure |
nrfx_usbd_handler_desc_t | USBD transfer descriptor |
nrfx_usbd_handler_t | Universal transfer handler |
nrfx_usbd_setup_t | Setup packet structure |
nrfx_usbd_transfer_t | Total transfer configuration |
nrfx_wdt_config_t | Struct for WDT initialization |
optiga_comms | Optiga comms structure |
optiga_hash_context | To specify the hash context information |
pal_gpio | Structure defines the PAL GPIO configuration |
pal_i2c | PAL I2C context structure |
parsed_ndef_msg_1_t | Memory allocated for a one-record message |
parsed_ndef_msg_2_t | Memory allocated for a two-record message |
pcal6408a_instance_t | Structure containing expander instance |
pd_data_conf_private_t | Private information which is passed with PD-DATA.confirm. Not covered by standard |
pd_data_conf_t | PD-DATA.confirm parameters |
pd_data_ind_private_t | Private information which is passed with PD-DATA.indication. Not covered by standard |
pd_data_ind_t | PD-DATA.indication parameters |
pd_data_req_t | PD-DATA.request parameters |
phy_pib_item_t | PHY PIB attribute type sizes |
phy_plme_ed_mem_t | This structure holds static data of this module |
pib_id_t | United PIB attribute identifiers |
plme_cca_conf_t | PLME-CCA.confirm parameters |
plme_ed_conf_t | PLME-ED.confirm parameters |
plme_get_conf_t | PLME-GET.confirm parameters |
plme_get_req_t | PLME-GET.request parameters |
plme_set_conf_t | PLME-SET.confirm parameters |
plme_set_req_t | PLME-SET.request parameters |
plme_trx_conf_t | PLME-TRX.confirm parameters |
plme_trx_req_t | PLME-SET_TRX_STATE.request parameters |
pm_conn_config_req_evt_t | Parameters specific to the PM_EVT_CONN_CONFIG_REQ event |
pm_conn_sec_config_t | Configuration of a security procedure |
pm_conn_sec_params_req_evt_t | Parameters specific to the PM_EVT_CONN_SEC_PARAMS_REQ event |
pm_conn_sec_start_evt_t | Events parameters specific to the PM_EVT_CONN_SEC_START event |
pm_conn_sec_status_t | Security status of a connection |
pm_conn_secure_failed_evt_t | Parameters specific to the PM_EVT_CONN_SEC_FAILED event |
pm_conn_secured_evt_t | Parameters specific to the PM_EVT_CONN_SEC_SUCCEEDED event |
pm_evt_t | An event from the Peer Manager module |
pm_failure_evt_t | Standard parameters for failure events |
pm_peer_data_bonding_t | Data associated with a bond to a peer |
pm_peer_data_local_gatt_db_t | Data on a local GATT database |
pm_peer_data_update_failed_t | Parameters specific to the PM_EVT_PEER_DATA_UPDATE_FAILED event |
pm_peer_data_update_succeeded_evt_t | Parameters specific to the PM_EVT_PEER_DATA_UPDATE_SUCCEEDED event |
public_key_from_host | To specifiy the Public Key details (key, size and algorithm) |
ral_mem_t | |
regcertdatalist_t | IEEE 11073-20601 Regulatory Certification Data List Structure |
RSAPrivContext_t | |
RSAPubContext_t | |
SaSi_PalDmaBlockInfo_t | |
SaSi_PalListItem | |
SaSiAesHwKeyData_t | |
SaSiAesUserContext_t | |
SaSiAesUserKeyData_t | |
sAuthMsg_d | Structure to specify authentication command parameters |
sAuthScheme_d | Structure to specify authentication Scheme parameters |
sbBlob_d | Structure to specify a byte stream consisting of length and data pointer |
sCalcHash_d | Structure to specify parameters for Hash generation |
sCalcSignOptions_d | Structure to specify parameters for signature generation |
sCalcSSecOptions_d | Structure to specify parameters for shared secret calculation |
sCallBack_d | Structure to specify Call back parameters for Get Message |
scan_evt_t | Structure for Scanning Module event data |
sCL_d | Structure containing Crypto Layer information |
sCmdResponse_d | Structure to receive the response of the device for a command |
sConfigCL_d | Structure to configure Crypto Layer |
sConfigRL_d | Structure to configure Record Layer |
sConfigTL_d | Structure to configure Transport Layer |
sContextInfo_d | Structure to specify the information for context information |
sdc_evt_t | SDC event structure |
sdc_type_t | SDC type information structure |
sDeriveKeyOptions_d | Structure to specify parameters for derive key generation |
sdk_mapped_flags_key_list_t | Type used to present a subset of the registered keys |
sec_aes_ccm_req_t | AES CCM request |
sensorsim_cfg_t | Triangular waveform sensor simulator configuration |
sensorsim_state_t | Triangular waveform sensor simulator state |
ser_ble_gap_app_keyset_t | GAP connection - keyset mapping structure |
ser_ble_gap_conn_keyset_t | GAP connection - keyset mapping structure |
ser_ble_user_mem_t | Connection - user memory mapping structure |
ser_hal_transport_evt_phy_error_params_t | Struct containing parameters of event of type SER_HAL_TRANSP_EVT_PHY_ERROR |
ser_hal_transport_evt_rx_pkt_received_params_t | Struct containing parameters of event of type SER_HAL_TRANSP_EVT_RX_PKT_RECEIVED |
ser_hal_transport_evt_t | Struct containing events from the Serialization HAL Transport layer |
ser_phy_evt_hw_error_params_t | A struct containing parameters of event of type SER_PHY_EVT_HW_ERROR |
ser_phy_evt_rx_buf_request_params_t | A struct containing parameters of event of type SER_PHY_EVT_RX_BUF_REQUEST |
ser_phy_evt_rx_pkt_received_params_t | A struct containing parameters of event of type SER_PHY_EVT_RX_PKT_RECEIVED |
ser_phy_evt_t | A struct containing events from a Serialization PHY module |
ser_phy_hci_evt_hw_error_params_t | Struct containing parameters of event of type SER_PHY_HCI_SLIP_EVT_HW_ERROR |
ser_phy_hci_pkt_params_t | Struct representing a PHY HCI packet |
ser_phy_hci_slip_evt_t | Struct containing events from the Serialization PHY module |
sercon_ble_user_mem_t | Connection - user memory mapping structure |
sfloat_t | SFLOAT format (IEEE-11073 16-bit FLOAT, meaning 4 bits for exponent (base 10) and 12 bits mantissa) |
sGetData_d | Structure to specify GetDataObject command parameters |
sha256_context_t | Current state of a hash operation |
sHandshake_d | Structure containing Handshake related data |
sHardwareCrypto_d | Structure for Hardware Crypto |
sHashinfo | Structure to specify hash information |
sKeyPairOption_d | Structure to specify parameters for Key Pair Generation |
slip_t | Representation of a SLIP packet |
sLogger_d | Structure to Logger |
sOIDInfo_d | Structure to specify OID information |
song_hdr_info_t | Song file header info portion |
song_hdr_sec_t | Song file header security info |
song_info | |
song_info_cache_t | Cache for information related to the currently loaded song |
song_metadata_t | Metadata info stored in flash |
song_program_state_t | State of song programming |
sOpenApp_d | Structure to specify open application command parameters |
sOutKeyPair_d | Structure to return key pair as output |
spi_master_config_t | Struct containing configuration parameters of the SPI master |
spi_master_evt_t | Struct containing parameters of the SPI MASTER event |
sProcCryptoData_d | Structure to specify ProcUpLink/ProcDownLink command parameters |
sProcMsgData_d | Structure to specify parameters for (D)TLS handshake messages |
sPubKeyInput_d | Structure to specify public key for verify hash |
sRL_d | Structure containing Record Layer information |
sRngOptions_d | Structure to specify option to generate random number |
sSetData_d | Structure to specify SetDataObject command parameters |
sTL_d | Structure holding Transport Layer Information |
sUint64 | Structure to store the record sequence number |
sVerifyOption_d | Structure to specify parameters for Signature verification |
SW_Shared_CRYS_RSAPrimeData_t | |
sx1509b_instance_t | Structure containing expander instance |
sys_event_desc_t | Event descriptor |
sys_fsm_const_descriptor_t | Constant FSM descriptor which can reside in read-only memory |
sys_fsm_t | FSM dynamic descriptor, holding the current state of the FSM |
sys_fsm_transition_t | FSM transition description (item of FSM transition table) |
sys_list_head | |
sys_queue_item_s | Queue item descriptor |
sys_ringbuffer_t | |
sys_timer_t | Timer descriptor |
tdt_config_t | TDT Local Config Struct |
tile_ble_env_t | |
tile_button_driver | |
tile_checked_tag | |
tile_conn_params | |
tile_env_tag | Tile environment data. Lost at reboot |
tile_gap_driver | |
tile_gatt_db_t | |
tile_persist_tag | |
tile_random_driver | |
tile_song_module | |
tile_song_tps_module_t | |
tile_tdg_module | |
tile_tdi_module | |
tile_tdt_module | |
tile_test_module | |
tile_timer_driver | |
tile_tmd_module | |
tile_toa_module | |
tile_tpi_module | |
tile_unchecked_tag | |
tlv_block_t | TLV block descriptor |
toa_channel_tag | |
type_2_tag_capability_container_t | Descriptor for the Capability Container (CC) bytes of a Type 2 Tag |
type_2_tag_serial_number_t | Descriptor for the internal bytes of a Type 2 Tag |
type_2_tag_t | Type 2 Tag descriptor |
uda1380_iface_t | UDA1380 interface |
uda1380_reg_t | UDA1380 register descriptor |
uint8_array_t | Byte array type |
ulong_union_t | Uint32_t type presentation as an union |
uMsgParams_d | Union to specify message specific parameters |
sMsgParamCert_d | Certificate Params |
sMsgParamCH_d | Client Hello Params |
uri_payload_desc_t | Type of description of the payload of a URI record |
ushort_union_t | Uint16_t type presentation as an union |
win_launchapp_payload_desc_t | Type of description of payload of Windows LaunchApp record |