The set command subscribes Coverage Enhancement (CE) notifications and reads current
parameters.
Syntax:
+CEINFO=<reporting>
Notification
syntax:
+CEINFO: <reporting>,<CE_Enabled>,<UE_State>,<Downlink_Repetition_Factor>,
<Uplink_Repetition_Factor>,<RSRP>,<CINR>
<UE_State>
is not between double quotation marks.
- +CME ERROR code
- 528 – Not allowed when power off warning is active.
The set command parameters and their defined values are the following:
- <reporting>
- 0 – Unsubscribe unsolicited notifications
- 1 – Subscribe unsolicited notifications
- <CE_Enabled>
- 0 – Serving cell does not support CE mode A/B
- 1 – Serving cell supports CE mode A/B
- <UE_State>
- User Equipment (UE) state at the time of the report.1
- I – Idle
- R – RACH
- C – Connected
- <Downlink_Repetition_Factor>
- Downlink repetition factor.
- If <UE_State> is Idle or RACH, it is set to
mpdcch-NumRepetition according to the current radio condition (that is,
Reference Signal Received Power (RSRP)) and prach-ParametersListCE-r13 in SIB2 if the
access technology is LTE-M. It is set to
npdcch-NumRepetitions according to the current radio condition and
NPRACH-Parameters-NB-r13 in SIB2-NB if the access technology is Narrowband Internet of Things (NB-IoT).
- If <UE_State> is Connected, it is set to mpdcch-NumRepetition
for the radio bearer if the access technology is LTE-M. It is set to
npdcch-NumRepetitions for the radio bearer if the access technology is NB-IoT.
- <Uplink_Repetition_Factor>
- Uplink repetition factor.
- If <UE_State> is Idle, it is set to
numRepetitionPerPreambleAttempt accordig to the current radio condition.
- If <UE_State> is RACH, it is set to
numRepetitionPerPreambleAttempt selected by UE.
- If <UE_State> is Connected, it is set to repetition number for
PUSCH if the access technology is LTE-M. It is set to repetition number for NPUSCH if
the access technology is NB-IoT.
- <RSRP>
- Current RSRP level at the time of the report.1 Numerical range in dBm.
- 255 – Not known or not detectable.
- <CINR>
- Current CINR level at the time of the report1. Numerical range in dB.
- 127 – Not known or not detectable.
The following command example subscribes unsolicited CE
notifications:
AT+CEINFO=1
OK
The following is an example of an
unsolicited CE notification:
+CEINFO: 1,1,C,5,3,-50,10
1 The value corresponds to the
last value that has been stored before the time of report. For example, when releasing an
RRC connection, the transition from connection to idle state and the next
<UE_State> being stored and reported can take several
seconds.