[78] TIMER: High current consumption when using timer STOP task only

This anomaly applies to Revision 1, build codes CKAA-Cx0, QIAA-Cx0.

It was inherited from the previous IC revision Engineering C.

Symptoms

Increased current consumption when the timer has been running and the STOP task is used to stop it.

Conditions

The timer has been running (after triggering a START task) and then it is stopped using a STOP task only.

Consequences

Increased current consumption.

Workaround

Use the SHUTDOWN task after the STOP task or instead of the STOP task.