Continuous Glucose Monitoring Service (CGMS) module. More...
Modules | |
Continuous Glucose Monitoring Service database | |
Continuous Glucose Monitoring Service database module. | |
Continuous Glucose Monitoring Service Measurement | |
Continuous Glucose Monitoring Service Measurement module. | |
Record Access Control Point | |
Continuous Glucose Monitoring Service RACP module. | |
Specific Operations Control Point | |
Continuous Glucose Monitoring Service SOCP module. | |
Session Start Time | |
Continuous Glucose Monitoring Service SST module. | |
Enumerations | |
Structures | |
Types | |
Functions | |
Macros | |
#define | NRF_BLE_CGMS_DEF(_name) |
Macro for defining a nrf_ble_cgms instance. More... | |
CGM Feature characteristic defines | |
#define | NRF_BLE_CGMS_FEAT_CALIBRATION_SUPPORTED (0x01 << 0) |
Calibration supported. | |
#define | NRF_BLE_CGMS_FEAT_PATIENT_HIGH_LOW_ALERTS_SUPPORTED (0x01 << 1) |
Patient High/Low Alerts supported. | |
#define | NRF_BLE_CGMS_FEAT_HYPO_ALERTS_SUPPORTED (0x01 << 2) |
Hypo Alerts supported. | |
#define | NRF_BLE_CGMS_FEAT_HYPER_ALERTS_SUPPORTED (0x01 << 3) |
Hyper Alerts supported. | |
#define | NRF_BLE_CGMS_FEAT_RATE_OF_INCREASE_DECREASE_ALERTS_SUPPORTED (0x01 << 4) |
Rate of Increase/Decrease Alerts supported. | |
#define | NRF_BLE_CGMS_FEAT_DEVICE_SPECIFIC_ALERT_SUPPORTED (0x01 << 5) |
Device Specific Alert supported. | |
#define | NRF_BLE_CGMS_FEAT_SENSOR_MALFUNCTION_DETECTION_SUPPORTED (0x01 << 6) |
Sensor Malfunction Detection supported. | |
#define | NRF_BLE_CGMS_FEAT_SENSOR_TEMPERATURE_HIGH_LOW_DETECTION_SUPPORTED (0x01 << 7) |
Sensor Temperature High-Low Detection supported. | |
#define | NRF_BLE_CGMS_FEAT_SENSOR_RESULT_HIGH_LOW_DETECTION_SUPPORTED (0x01 << 8) |
Sensor Result High-Low Detection supported. | |
#define | NRF_BLE_CGMS_FEAT_LOW_BATTERY_DETECTION_SUPPORTED (0x01 << 9) |
Low Battery Detection supported. | |
#define | NRF_BLE_CGMS_FEAT_SENSOR_TYPE_ERROR_DETECTION_SUPPORTED (0x01 << 10) |
Sensor Type Error Detection supported. | |
#define | NRF_BLE_CGMS_FEAT_GENERAL_DEVICE_FAULT_SUPPORTED (0x01 << 11) |
General Device Fault supported. | |
#define | NRF_BLE_CGMS_FEAT_E2E_CRC_SUPPORTED (0x01 << 12) |
E2E-CRC supported. | |
#define | NRF_BLE_CGMS_FEAT_MULTIPLE_BOND_SUPPORTED (0x01 << 13) |
Multiple Bond supported. | |
#define | NRF_BLE_CGMS_FEAT_MULTIPLE_SESSIONS_SUPPORTED (0x01 << 14) |
Multiple Sessions supported. | |
#define | NRF_BLE_CGMS_FEAT_CGM_TREND_INFORMATION_SUPPORTED (0x01 << 15) |
CGM Trend Information supported. | |
#define | NRF_BLE_CGMS_FEAT_CGM_QUALITY_SUPPORTED (0x01 << 16) |
CGM Quality supported. | |
Continuous Glucose Monitoring type | |
#define | NRF_BLE_CGMS_MEAS_TYPE_CAP_BLOOD 0x01 |
Capillary Whole blood. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_CAP_PLASMA 0x02 |
Capillary Plasma. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_VEN_BLOOD 0x03 |
Venous Whole blood. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_VEN_PLASMA 0x04 |
Venous Plasma. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_ART_BLOOD 0x05 |
Arterial Whole blood. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_ART_PLASMA 0x06 |
Arterial Plasma. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_UNDET_BLOOD 0x07 |
Undetermined Whole blood. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_UNDET_PLASMA 0x08 |
Undetermined Plasma. | |
#define | NRF_BLE_CGMS_MEAS_TYPE_FLUID 0x09 |
Interstitial Fluid (ISF). | |
#define | NRF_BLE_CGMS_MEAS_TYPE_CONTROL 0x0A |
Control Solution. | |
CGM sample location | |
#define | NRF_BLE_CGMS_MEAS_LOC_FINGER 0x01 |
Finger. | |
#define | NRF_BLE_CGMS_MEAS_LOC_AST 0x02 |
Alternate Site Test (AST). | |
#define | NRF_BLE_CGMS_MEAS_LOC_EAR 0x03 |
Earlobe. | |
#define | NRF_BLE_CGMS_MEAS_LOC_CONTROL 0x04 |
Control solution. | |
#define | NRF_BLE_CGMS_MEAS_LOC_SUB_TISSUE 0x05 |
Subcutaneous tissue. | |
#define | NRF_BLE_CGMS_MEAS_LOC_NOT_AVAIL 0x0F |
Sample Location value not available. | |
CGM Measurement Sensor Status Annunciation | |
#define | NRF_BLE_CGMS_STATUS_SESSION_STOPPED (0x01 << 0) |
Status: Session Stopped. | |
#define | NRF_BLE_CGMS_STATUS_DEVICE_BATTERY_LOW (0x01 << 1) |
Status: Device Battery Low. | |
#define | NRF_BLE_CGMS_STATUS_SENSOR_TYPE_INCORRECT_FOR_DEVICE (0x01 << 2) |
Status: Sensor type incorrect for device. | |
#define | NRF_BLE_CGMS_STATUS_SENSOR_MALFUNCTION (0x01 << 3) |
Status: Sensor malfunction. | |
#define | NRF_BLE_CGMS_STATUS_DEVICE_SPECIFIC_ALERT (0x01 << 4) |
Status: Device Specific Alert. | |
#define | NRF_BLE_CGMS_STATUS_GENERAL_DEVICE_FAULT (0x01 << 5) |
Status: General device fault has occurred in the sensor. | |
CGM Measurement flags | |
#define | NRF_BLE_CGMS_FLAG_TREND_INFO_PRESENT 0x01 |
CGM Trend Information Present. | |
#define | NRF_BLE_CGMS_FLAGS_QUALITY_PRESENT 0x02 |
CGM Quality Present. | |
#define | NRF_BLE_CGMS_STATUS_FLAGS_WARNING_OCT_PRESENT 0x20 |
Sensor Status Annunciation Field, Warning-Octet present. | |
#define | NRF_BLE_CGMS_STATUS_FLAGS_CALTEMP_OCT_PRESENT 0x40 |
Sensor Status Annunciation Field, Cal/Temp-Octet present. | |
#define | NRF_BLE_CGMS_STATUS_FLAGS_STATUS_OCT_PRESENT 0x80 |
Sensor Status Annunciation Field, Status-Octet present. | |
Byte length of various commands (used for validating, encoding, and decoding data). | |
#define | NRF_BLE_CGMS_MEAS_OP_LEN 1 |
Length of the opcode inside the Glucose Measurement packet. | |
#define | NRF_BLE_CGMS_MEAS_HANDLE_LEN 2 |
Length of the handle inside the Glucose Measurement packet. | |
#define | NRF_BLE_CGMS_MEAS_LEN_MAX |
Maximum size of a transmitted Glucose Measurement. More... | |
#define | NRF_BLE_CGMS_MEAS_REC_LEN_MAX 15 |
Maximum length of one measurement record. Size 1 byte, flags 1 byte, glucose concentration 2 bytes, offset 2 bytes, status 3 bytes, trend 2 bytes, quality 2 bytes, CRC 2 bytes. | |
#define | NRF_BLE_CGMS_MEAS_REC_LEN_MIN 6 |
Minimum length of one measurement record. Size 1 byte, flags 1 byte, glucose concentration 2 bytes, offset 2 bytes. | |
#define | NRF_BLE_CGMS_MEAS_REC_PER_NOTIF_MAX |
Maximum number of records per notification. We can send more than one measurement record per notification, but we do not want a a single record split over two notifications. More... | |
#define | NRF_BLE_CGMS_SOCP_RESP_CODE_LEN 2 |
Length of a response. Response code 1 byte, response value 1 byte. | |
#define | NRF_BLE_CGMS_FEATURE_LEN 6 |
Length of a feature. Feature 3 bytes, type 4 bits, sample location 4 bits, CRC 2 bytes. | |
#define | NRF_BLE_CGMS_STATUS_LEN 7 |
Length of a status. Offset 2 bytes, status 3 bytes, CRC 2 bytes. | |
#define | NRF_BLE_CGMS_MAX_CALIB_LEN 10 |
Length of a calibration record. Concentration 2 bytes, time 2 bytes, calibration 4 bits, calibration sample location 4 bits, next calibration time 2 bytes, record number 2 bytes, calibration status 1 byte. | |
#define | NRF_BLE_CGMS_CALIBS_NB_MAX 5 |
Maximum number of calibration values that can be stored. | |
#define | NRF_BLE_CGMS_SST_LEN 9 |
Length of the start time. Date time 7 bytes, time zone 1 byte, DST 1 byte. | |
#define | NRF_BLE_CGMS_CRC_LEN 2 |
Length of the CRC bytes (if used). | |
#define | NRF_BLE_CGMS_SRT_LEN 2 |
Length of the Session Run Time attribute. | |
#define | NRF_BLE_CGMS_SOCP_RESP_LEN |
Max lenth of a SOCP response. More... | |
#define | NRF_BLE_CGMS_RACP_PENDING_OPERANDS_MAX 2 |
Continuous Glucose Monitoring Service (CGMS) module.
This module implements a sensor for the Continuous Glucose Monitoring Service. The sensor is a GATT Server that sends CGM measurements to a connected CGMS Collector. The CGMS Sensor stores records that can be accessed with the Record Access Control Point (RACP). The collector can access the features and status of the sensor. Session Run Time and Session Start Time can be used to convey timing information between the sensor and the collector. The Specific Operations Control Point is used to stop and start monitoring sessions, among other things.
#define NRF_BLE_CGMS_DEF | ( | _name | ) |
Macro for defining a nrf_ble_cgms instance.
_name | Name of the instance. |
#define NRF_BLE_CGMS_MEAS_LEN_MAX |
Maximum size of a transmitted Glucose Measurement.
#define NRF_BLE_CGMS_MEAS_REC_PER_NOTIF_MAX |
Maximum number of records per notification. We can send more than one measurement record per notification, but we do not want a a single record split over two notifications.
#define NRF_BLE_CGMS_SOCP_RESP_LEN |
Max lenth of a SOCP response.