The Nordic Thingy:53™ has a range of solder bridges for enabling and disabling functionalities. Changes to these are not needed for normal use of the Nordic Thingy:53.
The following table provides a complete overview of the solder bridges on the Nordic Thingy:53.
Solderbridge | Default | Position | Function |
---|---|---|---|
SB1 | Closed | Top | Cut to disconnect magnetometer from the SDA and SCL Inter-integrated Circuit (I2C) lines. |
SB2 | |||
SB3 | Bottom | Solder to connect the SDA line from the magnetometer to the ASDA line of the IMU. | |
SB4 | Open | Solder to connect the SCL line from the magnetometer to the ASCL line of the IMU. | |
SB5 | Top | Short to bypass load switch U4. | |
SB6 | Closed | Cut to disconnect the ANT_SEL pin on the nRF21540 RF FEM from ground. | |
SB7 | Open | Short to connect the MODE pin on the nPM1100 PMIC to P0.08. | |
SB20 | Short to bypass load switch U5. | ||
SB21 | Short to bypass load switch U11. | ||
SB22 | Short to bypass load switch U14. |