The current drawn by the nRF9161
System in Package (SiP) can be measured using an ampere meter.
Complete the following steps to measure the average
current drawn by the nRF9161 SiP:
-
Set the average timing of the ampere meter to a long interval, such as 1 s or
longer.
-
Set the dynamic range of the ampere meter between 1 uA and 15 mA so that it is
wide enough to provide accurate measurements.
-
To connect the ampere meter in series with the nRF9161 DK,
connect the ampere meter to the pins on connector P22.
Figure 1. Current measurement with an ampere meter
Note: Use a high-speed, high-dynamic-range ampere meter for the best and most
reliable measurements. Switching the current range in the ampere meter can
affect the power supply to the nRF9161 DK. High speed and
bandwidth are required to detect rapid changes in the current consumption in
the nRF9161 DK.