nRF5340 v2.0.2

Solder bridge configuration

The nRF5340 DK has a range of solder bridges for enabling or disabling functionality on the Development Kit (DK). Changes to these are not needed for normal use of the DK.

The following table is an overview of the solder bridges on the nRF5340 DK.

Table 1. Solder bridge configuration
Solder bridge Default Function
SB1 Closed Cut to disconnect the 32.768 kHz on P0.01
SB2 Closed Cut to disconnect the 32.768 kHz on P0.00
SB3 Open Short to enable P0.01 as normal GPIO
SB4 Open Short to enable P0.00 as normal GPIO
SB5 Closed Cut to disconnect LED1
SB6 Closed Cut to disconnect LED2
SB7 Closed Cut to disconnect LED3
SB8 Closed Cut to disconnect LED4
SB9 Open Short to bypass peripheral power switch
SB10 Closed Cut to disconnect the QSPI memory from P0.16
SB11 Closed Cut to disconnect the QSPI memory from P0.17
SB12 Closed Cut to disconnect the QSPI memory from P0.13
SB13 Closed Cut to disconnect the QSPI memory from P0.18
SB14 Closed Cut to disconnect the QSPI memory from P0.14
SB15 Closed Cut to disconnect the QSPI memory from P0.15
SB16 Closed Cut to disconnect QSPI memory power supply from VDD_PER
SB17 Open Short to connect QSPI memory power supply to VDD
SB18 Open Short to connect QSPI memory power supply to VDD_nRF
SB20 Open Short to enable P0.16 as a normal GPIO
SB21 Open Short to enable P0.17 as a normal GPIO
SB22 Open Short to enable P0.13 as a normal GPIO
SB23 Open Short to enable P0.18 as a normal GPIO
SB24 Open Short to enable P0.14 as a normal GPIO
SB25 Open Short to enable P0.15 as a normal GPIO
SB26 Closed Cut to disable the rgw pull-up resistor of the RESET line
SB27 Closed Cut to disconnect the nRF5340 CTS line from the signal switch and interface MCU
SB28 Closed Cut to disconnect the nRF5340 RTS line from the signal switch and interface MCU
SB29 Closed Cut to disconnect the nRF5340 RxD line from the signal switch and the interface MCU
SB30 Closed Cut to disconnect the nRF5340 TxD line from the signal switch and interface MCU
SB31 Open Short to bypass the USB detect switch
SB32 Open Short to permanently enable the I2C pull-up resistors
SB33 Closed Cut to permanently disable the I2C pull-up resistors
SB34 Open Short to bypass the power switch on the USB power
SB35 Open Short to bypass the power switch on the coin cell battery power
SB36 Open Short to bypass the power switch on the external supply power
SB37 Open Short to bypass the interface MCU power switch
SB38 Closed Cut to disable VDD power to the Arduino interface
SB39 Open Short to bypass the power switch for regulator, coin cell, or external supply
SB40 Closed Cut for current measurements of the VDD_nRF
SB41 Closed Cut for current measurements of the VDD_nRF_HV
SB42 Closed Cut to disconnect the RESET button from the application nRF5340 RESET pin when the interface MCU is disconnected
SB43 Open Short to connect the RESET button to the RESET pin on the Arduino interface
SB44 Open Short to connect the RESET pin on the Arduino interface to the nRF5340 reset pin
SB45 Open Short to connect the RESET pin on the Arduino interface to the interface nRF5340 reset pin when the interface MCU is disconnected
SB46 Open Short to connect the RESET pin on the Arduino interface to the interface MCU Boot when the interface MCU is disconnected
SB47 Open Short to enable power supply of the external device when using the debug out connector
SB48 Open Short to bypass the interface MCU USB power switch
SB50 Closed Cut to disconnect the nRF5340 CTS line from the signal switch and interface MCU
SB51 Closed Cut to disconnect the nRF5340 RTS line from the signal switch and interface MCU
SB52 Closed Cut to disconnect the nRF5340 RxD line from the signal switch and the interface MCU
SB53 Closed Cut to disconnect the nRF5340 TxD line from the signal switch and interface MCU
SB54 Closed Cut to disconnect the nRF5340 SWDIO line from the signal switch and interface MCU
SB55 Closed Cut to disconnect the nRF5340 SWDCLK line from the signal switch and interface MCU
SB56 Closed Cut to disconnect the nRF5340 RESET line from the signal switch and interface MCU
SB57 Closed Cut to disconnect the nRF5340 SWO line from the signal switch and the interface MCU
SB58 Closed Cut to disconnect voltage follower from external supply when SW10 is in ON position
SB59 Open Solder to connect debug in and trace reference voltage to VDD
SB60 Closed Cut to disconnect debug in and trace reference voltage from VDD_nRF'
SB80 Open Short to bypass the power switch for the VBUS of nRF5340
SB81 Open Short to bypass the power switch for the VDD_HV of nRF5340

The following table is a complete overview of the test points on the nRF5340 DK.