The set command measures or sets the AFC error value for a given frequency. The default
error value is 0.
The AFC measurement and set functions are described in the following sections.
AFC measurement
The AFC measurement function measures the AFC error value for a given frequency. The default error value is 0.
AFC set
The AFC set function allows to manually set the AFC error value in Hz or relative Q30 format, which can be used in RX and GNSS SNR tests if the AFC correction enabling parameter, for example <param4> in the RX SNR test, is 1. The value set with this command overwrites the value obtained with AFC measurement.