The read command reads the requested Paging Time Window (PTW)
parameters.
Response syntax:
%XPTW: <AcT-type>,<Requested_ptw_value>
The read response parameters and their defined values are the following:
- <AcT-type>
- 4 – Evolved Terrestrial Radio Access Network (E-UTRAN) (WB-S1 mode)
- 5 – E-UTRAN (NB-S1 mode)
- <Requested_ptw_value>
- String. Half a byte in 4-bit format. The PTW value refers to bits from 8 to 5 of octet
3 of the Extended Discontinuous Reception (eDRX) parameters information element (see
3GPP TS 24.008, subclause 10.5.5.32).
The following command example reads the requested PTW value(s):
AT%XPTW?
%XPTW: 4,"0110"
%XPTW: 5,"1110"
OK
Note:
- If the device supports many access technologies, each access technology is included in
a separate line as illustrated in the example above.
- The negotiated PTW value can be checked with the +CEDRXRDP
command.