nrf9160

Read command

The read command reads the requested Paging Time Window (PTW) parameters.

Response syntax:

%XPTW: <AcT-type>,<Requested_ptw_value>

The read response parameters and their defined values are the following:

<AcT-type>
4 – Evolved Terrestrial Radio Access Network (E-UTRAN) (WB-S1 mode)
5 – E-UTRAN (NB-S1 mode)
<Requested_ptw_value>
String. Half a byte in 4-bit format. The PTW value refers to bits from 8 to 5 of octet 3 of the Extended Discontinuous Reception (eDRX) parameters information element (see 3GPP TS 24.008, subclause 10.5.5.32).

The following command example reads the requested PTW value(s):

AT%XPTW?
%XPTW: 4,"0110"
%XPTW: 5,"1110"
OK
Note:
  • If the device supports many access technologies, each access technology is included in a separate line as illustrated in the example above.
  • The negotiated PTW value can be checked with the +CEDRXRDP command.