Priority

When multiple requests happen at the same time, the priority is as follows:

  1. VBAT and IBAT
  2. Battery temperature
  3. Die temperature
  4. VSYS
  5. VBUS

If a measurement has been requested but the measurement has not started, a higher priority can be requested.

In the case where a low priority measurement has been requested and the system has started the measurement, a higher priority can be requested. The system will complete the lower priority measurement before the higher priority measurement.