Radio Notification with concurrent peripheral and central connection events

The Peripheral links are arbitrarily positioned with respect to each other and to the Central links. Therefore, if a Peripheral connection event occurs too close to a Central connection event, the notification signal before the peripheral connection event might not be available to the application.

Figure 1 shows an example where the time distance between the central and the peripheral events is too small to allow the SoftDevice to trigger the ACTIVE notification signal.

Figure 1. Example: The gap between the links as a Central and the Peripheral is too small to trigger the notification signal

If the following condition is met:

tgap tndist

the notification signal will arrive, as illustrated in Figure 2.

Figure 2. Example: The gap between the links as a Central and the Peripheral is sufficient to trigger the notification signal