Central connection event

This section gives an overview of the power profile of the central connection event implemented in the SoftDevice.

Figure 1. Central connection event

Table 1. Central connection event
Stage Description Current Calculation1
(A) Pre-processing ION + IRTC + IX32k + ICPU,Flash
(B) Standby + XO ramp ION + IRTC + IX32k + ISTART,X16M
(C) Standby ION + IRTC + IX32k + IX16M
(D) Radio start ION + IRTC + IX32k + IX16M + ʃ(ISTART,TX) + ICPU,Flash
(E) Radio TX ION + IRTC + IX32k + IX16M + ITX,0dBM
(F) Radio turn-around ION + IRTC + IX32k + IX16M + ʃ(ISTART,RX) + ICPU,Flash
(G) Radio RX ION + IRTC + IX32k + IX16M + IRX
(H) Post-processing ION + IRTC + IX32k + ICPU,Flash
(I) Idle - connected ION + IRTC + IX32k
Important: When using the 32.768 kHz RC oscillator, IRC32k must be used instead of IX32k.
1 See the corresponding product specification for the symbol values.

Documentation feedback | Developer Zone | Updated 2016-04-08