[113] COMP: Single-ended mode with external reference is not functional

This anomaly applies to IC Rev. Rev 1, build codes QFAA-B00, QFAB-B00, CIAA-B00.

It was inherited from the previous IC revision Engineering C.

Symptoms

COMP output is not correct.

Conditions

COMP is used in single-ended mode with external reference.

Consequences

COMP cannot be used in this mode.

Workaround

None.