Code Name Description
0x00 SUCCESS The command completed successfully.
0x80 ERROR_UNKNOWN An unknown error occured.
0x81 ERROR_INTERNAL An internal error occured. This indicates that there could be something wrong with the serial command handler implementation.
0x82 ERROR_CMD_UNKNOWN The command was not recognized by the mesh device.
0x83 ERROR_INVALID_STATE The command was received at a time when the state of the device prevents it from processing it.
0x84 ERROR_INVALID_LENGTH The length of the received command was incorrect.
0x85 ERROR_INVALID_PARAMETER One or more of the command parameters were incorrect.
0x86 ERROR_BUSY The mesh device was busy processing a previous command, or a required resources was temporarily unavailable.
0x87 ERROR_INVALID_DATA Invalid data was sent as part of the command parameters.
0x8e ERROR_REJECTED The command was rejected, either because of insufficient resources or because the requested resource was temporarily unavailable.
0x93 ERROR_TIMEOUT The command processing was aborted because of a time-out.
0x98 ERROR_INVALID_KEY_DATA The key data sent as part of the command parameters was invalid.